Power Supply for PMT Modules C7169
The C7169 is a power supply unit for driving photosensor modules. Both drive voltages and control voltages can be supplied from this one unit. Applicable products: H5773/H5783/H6779/H6780 Series, H5784 Series H7710/H8567 Series, H7711/H7712/H8568/H8569 Series H7732 Series, H7826 Series, H7827 Series, H8249 Series
Parameter Output Voltage Max. Input Current Control Voltage (variable voltage range) AC Input Voltage Input Power Frequency Operating Ambient Temperature Storage Temperature Output Connector Dimensional Outlines Weight
Value 15 0.3 (+15 V), 0.2 (-15 V) 0 to +1.2 100 to 240 50/60 +5 to +50 -20 to+50 Binding post 147 x 61 x 200 Approx.1.2
Unit V A V V Hz C C -- mm kg
Amplifier Units
These are amplifier units for photomultiplier tubes and current output type PMT modules. C7319: Switchable between 2 frequency bandwidths and 3 current/voltage conversion coefficients. Ideal for applications requiring low noise and high gain. C6438: Wide bandwidth from DC to 50 MHz and gain of 20 dB. (-01 type is 54 dB) C5594: High cut off frequency of 1.5 GHz. Faithfully amplifies high-speed output pulses. The input/output connector can be selected from the SMA or BNC types.
From left: C7319, C6438, C5594-44
C7319 C5594-44 *6 C6438 C6438-01 Parameter Frequency Bandwidth DC to 20 kHz or DC to DC to 50 MHz DC to 50 MHz 50 kHz to 1.5 GHz (-3 dB) 200 kHz (switchable)*1 2 4 (approx. 10 times) 54 3 *4 (approx. 500 times) 36 *4 (approx. 63 times) Voltage Gain --* 20 3 * Current-to-Voltage 100 mV/A, 1 V/A 0.5 mV/A *5 25 mV/A *5 3.15 mV/A *5 Conversion Factor or 10 V/A (switchable) Amplifier Input (output) Current (inverted) Voltage (non-inverted) Voltage (non-inverted) -Voltage (non-inverted) Input Impedance -- *2 50 50 50 50 50 Recommended Load Resistance -- 50 1 *4 1 *4 13 *3 Max. Output Signal Voltage -2.5 *4 BNC-R BNC-R BNC-R Input BNC-R BNC-R BNC-R BNC-R Connector Output BNC-R DIN (6-pin) DIN (6-pin) DIN (6-pin) Power -- 5 to 15 5 5 Input Voltage +12 to +16 16 55 80 Input Current Max. +95 60 x 43.2 x 65 60 x 43.2 x 65 60 x 43.2 x 65 Dimensions 54 x 17 x 33 Approx.170 Approx.160 Approx.160 Weight Approx.80
*1: Frequency bandwidth is limited to DC to 100 kHz at conversion coefficient of 10 V/A. *2: C7319 is current input type. *3: At 15 V Supply voltage and 10 k load resistance. *4: At 50 load resistance. *5: Value after current-to-voltage conversion by input impedance. *6: Contact our sales office for other connectors for C5594.
Unit -- dB -- -- V -- -- -- V mA mm g
56
Related Products Photon Counting Units C3866, C6465
These photon counting units contain an amplifier and discriminator to convert the single photoelectric pulses from a photomultiplier tube into a 5 V digital signal. The C3866 has an output linearity up to 1 x 107 S-1, and a high-speed counter is not required when set to division by 10. The C6465 has an output linearity up to 1 x 106 S-1, and an output pulse width of 30 ns allows it to be used with a general-purpose counter.
LLeft: C3866 Right: C6465
Parameter Input Impedance Discrimination Level (input conversion) Gain Required in PMT Prescaler Count Linearity Pulse-pair Resolution Output Signal Level Output Pulse Width Supply Voltage Input Output Connector Remote Power Dimensions Weight
C3866 50 -0.5 to -16 3 x 106 1/1 4 x 106 25 1/10 1 x 107 10
C-MOS 10 Depends on count rate. +5.2 0.2 V, 150 mA/-5.2 0.2 V, 300 mA BNC-R BNC-R BNC-R HIROSE SR30-10R-4S *1 88 x 32 x 170 Approx. 320
C6465 50 -2.2 to -31 5 x 106 -- 1 x 106 60 TTL positive logic 30 +5 V, 60 mA/-5 V, 120 mA BNC-R BNC-R -- DIN (6-pin) *2 60 x 43.2 x 105 Approx. 250
Unit mV -- s-1 ns -- ns -- -- -- -- -- mm g
*1: Supplied with a cable (1 m) attached to the mating plug (HIROSE SR30-10PQ-4P). *2: Supplied with a cable (1.5 m) attached to the mating plug.
Data Acquisition Units C8907, C8908
The C8907 and C8908 data acquisition units have a signal processing circuit that converts analog signals of a PMT module into digital data for output to a PC (personal conputer). Gate time/Integration time, number of reading and photomultiplier tube gain can be controlled from the PC. The C8907 and C8908 also provide output voltage necessary to operate a PMT module, making device setup and connection easier.
Left: PMT module (sold separately)s Right: C8907, C8908
C8908 Parameter C8907 Configuration Photon counting circuit + counter + CPU + interface Charge amp + ADC + CPU + interface -- Pulse-pair Resolution 20 12 ADC Resolution -- Interface RS-232C Gate Time / Integration Time 0.04 to 500 10 to 1000 (10 step) Dead Time 0.01 to 500 -- 1 to 127 -- Number of Reading at Fixed Set Reading Supply Voltage +5 Power cable (6-pin) Accessories (supplied) RS-232C cross cable H7826P, H7826P-01, H7732P-01, H7826 Series, H7732 Series, H6780 Series* Applicable PMT Modules H7732P-11, H5783P* H5783 Series*, H7710 / H8567 Series*
Unit -- ns bit -- ms ms -- V -- --
*: We can install a signal connector (BNC-P) and a power input connector (HIROSE HR 10A-7P-6P) to the cable ends of an applicable PMT module if needed (extra charge). Please specify the type of connector when placing your order.
57
Related Products
Counting Board M8784
The M8784 counting board is a PCI bus add-in board type counter. The M8784 functions as a photon counter when combined with a photon counting head, etc. The counter of the M8784 includes two counting circuits (double counter method) capable of counting input signals with no dead time. The internal memory allows pulse counting over extended periods with a high time resolution (10 s). A maximum of two M8784 boards can be simultaneously controlled from a PC, making it possible to perform simultaneous dual-channel measurements. Initial setting for the M8784 is simple and easy due to PnP (plug and play). You can start measurement on the day you receive the M8784. The M8784 is designed to install into a PCI bus slot of desktop computers and cannot be used with notebook-sized computers. When using a notebook computer, use the C8855 counting unit also available from Hamamatsu.
* Also ideal for long-term data collection such as in biological clock monitoring *)
This is an ideal feature when the time needed to record count data in the memory is longer than the time needed to transfer the count data to a PC and write it into the storage medium. This allows time-resolved measurement (minimum resolution: 10 s) over a long period of time . Memory recording time is calculated from "counter operation time x memory length". (Example: minimum resolution 10 s x maximum memory length 256 000 = 2.56 s) *) Standard sample software may not work at some conditions depending on the combination of measuring time and time resolution.
Please consult with our sales office in advance with information of your condition.
* Time-resolved measurement of chemiluminescence (minimum resolution 10 s) * Supports different kinds of measurements
The M8784 is fully controlled by DLL (dynamic link library) functions that come with the M8784. All information on these DLL functions is available to support software programming that handles various types of user measurement applications. Parameter Description / Value Number of Input Signals 1 ch Signal Input Level TTL positive logic Input Signal Pulse Width 8 ns or longer Input Impedance 50 Counter Method Double counter method Max.Count Rate Counter 50 MHz Max.Counter Capacity 232 counts/counter gate Counter Gate Mode Internal, external, START-STOP Internal Counter Gate Time Counter Gate 10 s to 10 s (1, 2, 5 step) External Counter Gate Time 100 ns or more Trigger Method Software or external trigger Trigger External Trigger Signal TTL negative logic Memory Method Double memory method Memory Capacity Memory 128 000 (when capacity of 232 is selected) / 256 000 (when capacity of 216 is selected) Memory Date Width 232 (32 bit) / 216 (16 bit) Signal Input General TTL negative logic / 8 bit Output Section Signal output Open collector / 8 bit Compatible OS Windows(R) 98/98SE/Me/2000 Bus Type PCI Supply Voltage 5 V / 1 A (supplied from PCI bus) Size Half size Weight 150 g Operating Ambient Temperature/Humidity +5 C to +45 C / 80 % or less (no condensation)
Supplied: CD-ROM (containing instruction manual, device driver, DLL, sample software, etc.), Signal input cable (E1168-22), General-purpose I/O connector (JAE: TXA20A-26PH1-D2P1-D1), Connection cable set (JAE: XHP-3, XHP-4) *: Sample software is configured from Lab VIEWTM of National Instruments, Inc. : Conforms to the EMC directive (89/336/EEC) of the European Union.
58
Related Products
Counting Unit C8855
The C8855 is a counting unit with a USB interface and can be used as a photon counter when combined with a photon counting head, etc. The counter of the C8855 has two counter circuits (double counter method) capable of counting input signals with no dead time. The USB interface easily connects to a notebook PC allowing measurement in an even wider application field. When used with a photon counting head, the C8855 supplies power (+5 V / 200 mA) necessary to operate the photon counting head. Since the C8855 is hot-swap compatible (plug and play compatible), it helps you set up measurement environment quickly. You can start measurement on the day the C8855 is delivered by using the sample software that comes with the C8855. The C8855 cannot be used in simultaneous dual- channel measurements or long-time measurements with a fast time resolution. In such applications, use the M8784 counting board also available from Hamamatsu.
* Time-resolved measurement (minimum resolution: 50 s) for monitoring chemiluminescence and biological clocks * Quick measurement setups (hot-swap compatible)
When software such as a device driver is installed into your PC beforehand, you can start measurement by just connecting the USB cable, without restarting the PC.
* Applicable to various measurement methods
The C8855 is fully controlled by DLL (dynamic link library) functions that come with the C8855. All information on these DLL functions is available to support software programming that handles various types of user measurement applications. Parameter Number of Input Signals Signal Input Level Input Signal Pulse Width Input Impedance Counter Method Max.Count Rate Counter Max.Counter Capacity Counter Gate Mode Counter Gate Internal Counter Gate Time Trigger Method Trigger External Trigger Signal General Output Section Voltage Output Compatible OS Interface Supply Voltage Dimensions Weight Operating Ambient Temperature/Humidity Input AC Adapter Output Description / Value 1 ch TTL positive logic 8 ns or longer 50 Double counter method 50 MHz 232 counts/counter gate Internal counter gate only 50 s to 10 s (1, 2, 5 step) Software or external trigger TTL negative logic Open collector / 2 bits +5 V / 200 mA Max. Windows(R) 98/98SE/Me/2000 USB (Ver. 1.1) +5 V / 500 mA Max. (supplied from accessory AC adapter) (W): 148 mm x (D): 96 mm x (H): 30 mm (excluding rubber feet and projecting parts) 300 g +5 C to +45 C / 80 % or less (no condensation) AC 90 V to AC 260 V 7 V / 1.6 A
Supplied: CD-ROM (containing instruction manual, device driver, DLL, sample software, etc.) USB cable, AC adapter, AC cable, power output connector *: Sample software is configured from Lab VIEWTM of National Instruments, Inc. : Conforms to the EMC directive (89/336/EEC) and the low voltage directive (73/23/EEC) of the European Union.
59


▲Up To Search▲   

 
Price & Availability of C7169

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X